<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15390</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: carrier larger than expected. Please remove carrier.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Remove the carrier on the load ramp and click the RESUME button from the
workstation dialog box. After about 30 seconds, the trendsetter will ask
the user to load another carrier. Load a correct-sized carrier and hit the
load button.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If the above action does not solve the problem, then the load ramp sensor may
not be working properly. Check for any debris blocking the sensor. If the sensor
is clean, use "set al lps 0" on the diagnostic monitor to bypass the sensor and
get the customer going, and arrange for field service.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The operator loaded an over-sized carrier on the load ramp.
</Cause>
<Cause>
The load plate sensor is dirty, damaged or misaligned.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_lps.xml</LinkAddress><LinkTitle>NVS: al lps</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:07 2008 PST
</Updated>